Category: Surgical

  • 210L.16.204.020

    Edenta Pilot Bur 210L 2.0mm diameter 16mm length depth markings at 9,11,13,15mm

    The efficiently cutting pilot bur is suitable as a pre-drill for all commonly used implant systems for initial preparation of the implant site. The specially designed bur tip and the good axial drilling properties enable precise drilling. The large chip escape channels guarantee rapid chip removal. The lasered depth marks at intervals of 2 millimetres provide exact visualisation of the penetration depth.

  • 210L.16.204.028

    Edental Pilot Bur 210L 2.8mm diameter 16mm length depth markings 9,11,13,15mm

    The efficiently cutting pilot bur is suitable as a pre-drill for all commonly used implant systems for initial preparation of the implant site. The specially designed bur tip and the good axial drilling properties enable precise drilling. The large chip escape channels guarantee rapid chip removal. The lasered depth marks at intervals of 2 millimetres provide exact visualisation of the penetration depth.

  • 210L.20.205.020

    Edenta Pilot Bur 210L 2.0mm diameter 20mm length depth markings 9,11,13,15,17,19mm

    The efficiently cutting pilot bur is suitable as a pre-drill for all commonly used implant systems for initial preparation of the implant site. The specially designed bur tip and the good axial drilling properties enable precise drilling. The large chip escape channels guarantee rapid chip removal. The lasered depth marks at intervals of 2 millimetres provide exact visualisation of the penetration depth.

  • 210L.20.205.028

    Edenta Pilot Bur 210L diameter 2.8mm length 20mm depth markings 9,11,13,15,17,19mm

    The efficiently cutting pilot bur is suitable as a pre-drill for all commonly used implant systems for initial preparation of the implant site. The specially designed bur tip and the good axial drilling properties enable precise drilling. The large chip escape channels guarantee rapid chip removal. The lasered depth marks at intervals of 2 millimetres provide exact visualisation of the penetration depth.

  • 229.205.025

    Edenta Trepan (Internal cutting diameter 2.5mm, external cutting diameter 3.5mm)

    Depth markings 2,4,6,8,10mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

     

  • 229.205.030

    Edenta Trepan (Internal cutting diameter 3.0mm, external cutting diameter 4.0mm)

    Depth markings 2,4,6,8,10mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229.205.035

    Edenta Trepan (Internal cutting diameter 3.5mm, external cutting diameter 4.5mm)

    Depth markings 2,4,6,8,10mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229.205.040

    Edenta Trepan (Internal cutting diameter 4.0mm, external cutting diameter 5.0mm)

    Depth markings 2,4,6,8,10mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229.205.050

    Edenta Trepan (Internal cutting diameter 5.0mm, external cutting diameter 6.0mm)

    Depth markings 2,4,6,8,10mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229.205.060

    Edenta Trepan (Internal cutting diameter 6.0mm, external cutting diameter 7.0mm)

    Depth markings 2,4,6,8,10mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229.205.080

    Edenta Trepan (Internal cutting diameter 8.0mm, external cutting diameter 9.0mm)

    Depth markings 2,4,6,8,10mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.030

    Edenta Trepan (Internal cutting diameter 3.0mm, external cutting diameter 4.0mm)

    Depth markings 6,8,10,12,14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.035

    Edenta Trepan (Internal cutting diameter 3.5mm, external cutting diameter 4.5mm)

    Depth markings 6,8,1012, 14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.040

    Edenta Trepan (Internal cutting diameter 4.0mm, external cutting diameter 5.0mm)

    Depth markings 6,8,1012,14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.045

    Edenta Trepan (Internal cutting diameter 4.5mm, external cutting diameter 5.5mm)

    Depth markings 6,8,10,12,14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.050

    Edenta Trepan (Internal cutting diameter 5.0mm, external cutting diameter 6.0mm)

    Depth markings 6,8,10,12,14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.060

    Edenta Trepan (Internal cutting diameter 6.0mm, external cutting diameter 7.0mm)

    Depth markings 6,8,10,12,14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.070

    Edenta Trepan (Internal cutting diameter 7.0mm, external cutting diameter 8.0mm)

    Depth markings 6,8,10,12,14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.

  • 229L.205.080

    Edenta Trepan (Internal cutting diameter 8.0mm, external cutting diameter 9.0mm)

    Depth markings 6,8,10,12,14mm

    Edenta Trepan is specially suitable for use in oral surgery and implantology for accurate, easy preparation of cylindrical bone grafts and bone extraction (Bone lid during apicectomies).  The good axial drilling properties enable precise drilling.  The efficiency cutting bone blades allow atraumatic treatment.  The laser depth markings 2mm apart provide exact visualisation of the penetration depth.